Errors & Fixes
SOLIDWORKS file is read-only — why and how to fix it
SOLIDWORKS opens a file read-only when someone else already has write access to it, when Windows marks it read-only, or when your PDM vault has not checked it out to you. On shared network folders the first person to open an assembly gets write access to it and to every part it uses — so a colleague's open assembly is the usual reason your part is read-only.

Applies to: SOLIDWORKS 2018–2027 on shared folders and with SOLIDWORKS PDM.
Most likely causes
- Someone else opened the file, or an assembly that uses it, first (most common)
- The Windows Read-only attribute is set on the file (common)
- PDM: the file is not checked out to you (PDM users)
- PDM and SOLIDWORKS locks disagree after a check-out (PDM users)
- You opened it with Open Read-only, or references open read-only by option (occasional)
Two kinds of read-only
| SOLIDWORKS read-only | Windows read-only attribute | |
|---|---|---|
| Where it comes from | Someone else has write access, Open Read-only, PDM | File Properties → Read-only |
| Can you save over it? | Yes, after a warning | No |
| How to clear it | Get Write Access / Reload when it is free | Clear the box in Properties |
Working on a shared folder without PDM

- Everybody turns on the multi-user environment options.
- Open referenced parts read-only by default, so opening an assembly does not lock every part for colleagues.
- When you need to edit a part, Get Write Access; when you are done, Make Read-Only to hand it back.
- Use Reload before saving if you see the "modified by another user" icon.
The SOLIDWORKS Tech Blog and TriMech both describe these options as a workaround: for a team working on the same files every day, a vault — SOLIDWORKS PDM — handles locking and version history properly.
Saving fails even with write access? See save errors. For keeping project files tidy in the first place, see file and folder setup.
Fixes, in order
1. Find out who has it open
On a shared folder only one person can save a file at a time. Ask whoever has the assembly open to close it — or to release the part with Make Read-Only (see the multi-user options below).
2. Clear the Windows read-only flag
In File Explorer, right-click the file → Properties and clear Read-only. Unlike SOLIDWORKS' own read-only mode, this attribute really blocks saving.
3. Turn on the multi-user environment
Tools → Options → System Options → Collaboration → Enable multi-user environment and Add shortcut menu items for multi-user environment. You get Get Write Access and Make Read-Only in the File menu and on components' right-click menus.
4. Get write access when it is free
When the other person has closed the file, use File → Get Write Access (parts) or right-click the component → Get Write Access. File → Reload first checks whether a newer copy was saved, so you do not overwrite their changes.
5. Let SOLIDWORKS tell you about changes
Check if files opened read-only have been modified by other users checks your read-only files every few minutes and shows a status-bar icon that opens the Reload dialog. Lightweight components are not checked.
6. PDM — check the file out
In a PDM vault a file is read-only until you check it out. If it is checked out but SOLIDWORKS still says read-only, GoEngineer's fix is to enable the multi-user options above and use Get Write Access; failing that, clear the Windows read-only flag.
7. Check the External References options
System Options → External References → Open referenced documents with read-only access deliberately opens parts read-only so others can edit them. Turn it off if you are the only user.
Sources
- SOLIDWORKS Tech Blog — Working with SOLIDWORKS files in a multi-user environment without PDM (Jun 2018)
- TriMech — Working Concurrently on SOLIDWORKS Files
- Hawk Ridge Systems — Managing Read-Only Access in SOLIDWORKS (Apr 2019)
- GoEngineer — SOLIDWORKS PDM: A File is Checked Out, But Still Read-Only (Jun 2017)
- Javelin — Working with SolidWorks Files on a Network (Mar 2014)
Checked November 2026. SOLID WORKS Club is independent; menu names can differ slightly between releases.
Frequently asked questions
Why does SOLIDWORKS open my part as read-only?
+
Usually because someone else has it — or an assembly that uses it — open with write access. It can also be the Windows read-only flag or a PDM file that is not checked out to you.
Can I save over a file opened read-only?
+
SOLIDWORKS warns you but lets you overwrite a file it opened read-only, which can wipe out a colleague's changes. The Windows read-only attribute, in contrast, blocks the save.
Where is Get Write Access?
+
In the File menu for parts and on the right-click menu of assembly components, once the multi-user options in System Options → Collaboration are turned on.
Related
- SOLIDWORKS PDMSOLIDWORKS PDM explained: PDM Standard vs Professional, the vault and Windows Explorer, check in and out, versions vs revisions, workflows, licences.
- SOLIDWORKS "Failed to save document" — how to fix itFix SOLIDWORKS 'Failed to save document' and unable to save errors: rebuild and save all, save locally, cloud folders, long paths, read-only files, antivirus.
- SOLIDWORKS missing references — unable to locate fileSOLIDWORKS "unable to locate file" when opening an assembly or drawing? How the search order works, how to repair references, and how to rename files safely.
- How to organize SOLIDWORKS files and foldersSet up SOLIDWORKS project folders that keep references intact — folder structure, naming, local vs network vs cloud sync, Pack and Go, rename tools and backups.